10 by 12 ft slab at 4 inches
Calculate the requirements for a residential slab measuring 10 ft by 12 ft at 4 in thickness with #4 bars at 18 in spacing. Ensure compliance with IRC R506 standards.
Formula SSC-2026.1
Formula SSC-2026.1 · 4,000 PSI
Order volume
1.63 yd³
1.246 m³ placed+waste
Order weight
6,600 lb
2,994 kg
80 lb bags
74
2 pallets at 42 bags
60 lb bags
98
0.45 ft³ yield each
Rebar
174.00 ft
16 × 20 ft · 16 × 6 m · 128 lb
Ready-mix vs bags
$393.89
Truck $393.89 · 80 lb bags $499.50
Grid lines are equalized so the drawing stays readable. The order count uses on-center spacing with a bar at each end of the layout, then holds concrete cover in the field.
| Item | Net | Waste | Order | Unit price | Line total | Source Spec Material / Tool |
|---|---|---|---|---|---|---|
| Ready-mix concrete | 1.48 yd³ | 10% | 1.63 yd³ / 1.246 m³ | USD | $268.89 | Source Spec Material / Tool |
| Short-load fee | Under 4 yd³ | — | 1 truck @ 10 yd³ | USD | $125.00 | Source Spec Material / Tool |
| 80 lb pre-mix bags | 66.7 bags | 10% | 74 bags | USD | $499.50 | Source Spec Material / Tool |
| 60 lb pre-mix bags | 88.9 bags | 10% | 98 bags | USD | $529.20 | Source Spec Material / Tool |
| #4 rebar sticks, 20 ft | 16 sticks | 10% | 18 sticks / 16 × 6 m | USD | $252.00 | Source Spec Material / Tool |
| Rebar chairs | 63 crossings | 10% | 70 chairs | USD | $19.60 | Source Spec Material / Tool |
| Tie wire rolls | 63 ties | 10% | 1 rolls | USD | $8.00 | Source Spec Material / Tool |
Source links open a product search on the Amazon storefront for the selected currency. SiteSpecCalc may earn a commission. The link does not change the quantities above.
Ready-mix truck
$393.89
0.16 nominal 10 yd³ loads · 1 to order
80 lb bags
$499.50
60 lb alternative $529.20 · delivery weight 6,600 lb
| Thickness | Order yd³ | Order m³ | 80 lb bags | Rebar ft | Ready-mix | 80 lb cost |
|---|---|---|---|---|---|---|
| 4 in | 1.63 | 1.246 | 74 | 191 | $393.89 | $499.50 |
| 5 in | 2.04 | 1.557 | 92 | 191 | $461.11 | $621.00 |
| 6 in | 2.44 | 1.869 | 110 | 191 | $528.33 | $742.50 |
Show the deterministic formula
Slab ft³ = L × W × thickness ÷ 12. Thickened-edge extra = footing band × (footing depth − slab thickness), with corner squares counted once.
yd³ = ft³ ÷ 27. m³ = ft³ × 0.0283168. Weight uses 150 lb/ft³, then the header converts that pound total at 1 lb = 0.45359237 kg. 80 lb bags yield 0.6 ft³ and 60 lb bags yield 0.45 ft³. Currency changes the price labels only.
Bars across a span = floor(span ÷ spacing) + 1. Order sticks = that count, plus 10, 5, or 15 percent waste, cut from 20 ft and 6 m stock. Chairs = one per grid intersection.
Contractor sign-off
Project: 10 by 12 ft slab at 4 inches
Prepared by
Date
Verified by (PE / electrician / inspector)
License number
Signature
This sheet is an estimate for ordering and layout discussion. It is not a sealed design. Confirm the quantities with a licensed local professional and the authority having jurisdiction before you buy or build.
Engineering notes
This calculator helps you determine the specifications for a residential concrete slab measuring 10 ft by 12 ft and 4 inches thick, reinforced with #4 bars spaced at 18 inches. Please note that soil design considerations are excluded from this calculation.
Refer to IRC R506 for guidelines on concrete slab design, ensuring your project meets the necessary structural integrity and safety standards.
Code reference
IRC R506
Field questions
- What is the purpose of using #4 bars in the slab?
- The #4 bars provide reinforcement to the concrete slab, helping to control cracking and improve load-bearing capacity.
- Why is soil design excluded from this calculation?
- Soil design is a separate consideration that depends on the specific site conditions and should be evaluated by a qualified professional.
- What does IRC R506 cover?
- IRC R506 provides guidelines for the design and construction of concrete slabs, including requirements for thickness, reinforcement, and curing.
Explore Related Engineering Calculations
- 14 by 12 ft slab at 8 inches
- 14 by 14 ft slab at 4 inches
- 8 by 8 ft slab at 8 inches
- 8 by 10 ft slab at 4 inches
- 14 by 14 ft slab at 5 inches
- 14 by 14 ft slab at 6 inches
- 50 Amp EV Charger Wire Size at 50, 75, and 100 Feet
- Deck Stair Stringer Calculator, 36 to 96 Inch Rise
- 6/12 Roof Pitch, Rafter Length, and Shingle Bundles
- 20 ft dry, US 48×40 pallets: Pallet Count, CBM, and Payload