14 by 10 ft slab at 5 inches
Calculate your residential slab requirements with our easy-to-use calculator. Ensure compliance with IRC R506 standards for a 14 ft by 10 ft slab with #4 bars at 18 in spacing.
Formula SSC-2026.1
Formula SSC-2026.1 · 4,000 PSI
Order volume
2.38 yd³
1.817 m³ placed+waste
Order weight
9,625 lb
4,366 kg
80 lb bags
107
3 pallets at 42 bags
60 lb bags
143
0.45 ft³ yield each
Rebar
198.00 ft
17 × 20 ft · 17 × 6 m · 145 lb
Ready-mix vs bags
$517.13
Truck $517.13 · 80 lb bags $722.25
Grid lines are equalized so the drawing stays readable. The order count uses on-center spacing with a bar at each end of the layout, then holds concrete cover in the field.
| Item | Net | Waste | Order | Unit price | Line total | Source Spec Material / Tool |
|---|---|---|---|---|---|---|
| Ready-mix concrete | 2.16 yd³ | 10% | 2.38 yd³ / 1.817 m³ | USD | $392.13 | Source Spec Material / Tool |
| Short-load fee | Under 4 yd³ | — | 1 truck @ 10 yd³ | USD | $125.00 | Source Spec Material / Tool |
| 80 lb pre-mix bags | 97.2 bags | 10% | 107 bags | USD | $722.25 | Source Spec Material / Tool |
| 60 lb pre-mix bags | 129.6 bags | 10% | 143 bags | USD | $772.20 | Source Spec Material / Tool |
| #4 rebar sticks, 20 ft | 17 sticks | 10% | 19 sticks / 17 × 6 m | USD | $266.00 | Source Spec Material / Tool |
| Rebar chairs | 70 crossings | 10% | 77 chairs | USD | $21.56 | Source Spec Material / Tool |
| Tie wire rolls | 70 ties | 10% | 1 rolls | USD | $8.00 | Source Spec Material / Tool |
Source links open a product search on the Amazon storefront for the selected currency. SiteSpecCalc may earn a commission. The link does not change the quantities above.
Ready-mix truck
$517.13
0.24 nominal 10 yd³ loads · 1 to order
80 lb bags
$722.25
60 lb alternative $772.20 · delivery weight 9,625 lb
| Thickness | Order yd³ | Order m³ | 80 lb bags | Rebar ft | Ready-mix | 80 lb cost |
|---|---|---|---|---|---|---|
| 4 in | 1.90 | 1.454 | 86 | 218 | $438.70 | $580.50 |
| 5 in | 2.38 | 1.817 | 107 | 218 | $517.13 | $722.25 |
| 6 in | 2.85 | 2.180 | 129 | 218 | $595.56 | $870.75 |
Show the deterministic formula
Slab ft³ = L × W × thickness ÷ 12. Thickened-edge extra = footing band × (footing depth − slab thickness), with corner squares counted once.
yd³ = ft³ ÷ 27. m³ = ft³ × 0.0283168. Weight uses 150 lb/ft³, then the header converts that pound total at 1 lb = 0.45359237 kg. 80 lb bags yield 0.6 ft³ and 60 lb bags yield 0.45 ft³. Currency changes the price labels only.
Bars across a span = floor(span ÷ spacing) + 1. Order sticks = that count, plus 10, 5, or 15 percent waste, cut from 20 ft and 6 m stock. Chairs = one per grid intersection.
Contractor sign-off
Project: 14 by 10 ft slab at 5 inches
Prepared by
Date
Verified by (PE / electrician / inspector)
License number
Signature
This sheet is an estimate for ordering and layout discussion. It is not a sealed design. Confirm the quantities with a licensed local professional and the authority having jurisdiction before you buy or build.
Engineering notes
This calculator helps you determine the specifications for a residential slab measuring 14 ft by 10 ft and 5 in thick, reinforced with #4 bars spaced 18 inches apart. Note that soil design considerations are excluded from this calculation.
For compliance, refer to the International Residential Code (IRC) R506, which outlines the requirements for concrete slabs in residential construction.
Code reference
IRC R506
Field questions
- What is the purpose of using #4 bars in the slab?
- Using #4 bars helps to reinforce the concrete slab, providing additional tensile strength and reducing the risk of cracking.
- Why is soil design excluded from this calculation?
- Soil design is a separate consideration that depends on local soil conditions and load-bearing capacity, which should be evaluated by a qualified engineer.
- What thickness is recommended for a residential slab?
- A thickness of 5 inches is commonly recommended for residential slabs, but this can vary based on specific load requirements and local building codes.
Explore Related Engineering Calculations
- 14 by 12 ft slab at 8 inches
- 14 by 14 ft slab at 4 inches
- 8 by 8 ft slab at 8 inches
- 8 by 10 ft slab at 4 inches
- 14 by 14 ft slab at 5 inches
- 14 by 14 ft slab at 6 inches
- 50 Amp EV Charger Wire Size at 50, 75, and 100 Feet
- Deck Stair Stringer Calculator, 36 to 96 Inch Rise
- 6/12 Roof Pitch, Rafter Length, and Shingle Bundles
- 20 ft dry, US 48×40 pallets: Pallet Count, CBM, and Payload