16 by 12 ft slab at 5 inches
Calculate the specifications for a residential slab measuring 16 ft by 12 ft at 5 in thick with #4 bars at 18 in spacing. Ensure compliance with IRC R506 standards.
Formula SSC-2026.1
Formula SSC-2026.1 · 4,000 PSI
Order volume
3.26 yd³
2.492 m³ placed+waste
Order weight
13,200 lb
5,987 kg
80 lb bags
147
4 pallets at 42 bags
60 lb bags
196
0.45 ft³ yield each
Rebar
276.00 ft
20 × 20 ft · 20 × 6 m · 203 lb
Ready-mix vs bags
$662.78
Truck $662.78 · 80 lb bags $992.25
Grid lines are equalized so the drawing stays readable. The order count uses on-center spacing with a bar at each end of the layout, then holds concrete cover in the field.
| Item | Net | Waste | Order | Unit price | Line total | Source Spec Material / Tool |
|---|---|---|---|---|---|---|
| Ready-mix concrete | 2.96 yd³ | 10% | 3.26 yd³ / 2.492 m³ | USD | $537.78 | Source Spec Material / Tool |
| Short-load fee | Under 4 yd³ | — | 1 truck @ 10 yd³ | USD | $125.00 | Source Spec Material / Tool |
| 80 lb pre-mix bags | 133.3 bags | 10% | 147 bags | USD | $992.25 | Source Spec Material / Tool |
| 60 lb pre-mix bags | 177.8 bags | 10% | 196 bags | USD | $1,058.40 | Source Spec Material / Tool |
| #4 rebar sticks, 20 ft | 20 sticks | 10% | 22 sticks / 20 × 6 m | USD | $308.00 | Source Spec Material / Tool |
| Rebar chairs | 99 crossings | 10% | 109 chairs | USD | $30.52 | Source Spec Material / Tool |
| Tie wire rolls | 99 ties | 10% | 1 rolls | USD | $8.00 | Source Spec Material / Tool |
Source links open a product search on the Amazon storefront for the selected currency. SiteSpecCalc may earn a commission. The link does not change the quantities above.
Ready-mix truck
$662.78
0.33 nominal 10 yd³ loads · 1 to order
80 lb bags
$992.25
60 lb alternative $1,058.40 · delivery weight 13,200 lb
| Thickness | Order yd³ | Order m³ | 80 lb bags | Rebar ft | Ready-mix | 80 lb cost |
|---|---|---|---|---|---|---|
| 4 in | 2.61 | 1.994 | 118 | 304 | $555.22 | $796.50 |
| 5 in | 3.26 | 2.492 | 147 | 304 | $662.78 | $992.25 |
| 6 in | 3.91 | 2.990 | 176 | 304 | $770.33 | $1,188.00 |
Show the deterministic formula
Slab ft³ = L × W × thickness ÷ 12. Thickened-edge extra = footing band × (footing depth − slab thickness), with corner squares counted once.
yd³ = ft³ ÷ 27. m³ = ft³ × 0.0283168. Weight uses 150 lb/ft³, then the header converts that pound total at 1 lb = 0.45359237 kg. 80 lb bags yield 0.6 ft³ and 60 lb bags yield 0.45 ft³. Currency changes the price labels only.
Bars across a span = floor(span ÷ spacing) + 1. Order sticks = that count, plus 10, 5, or 15 percent waste, cut from 20 ft and 6 m stock. Chairs = one per grid intersection.
Contractor sign-off
Project: 16 by 12 ft slab at 5 inches
Prepared by
Date
Verified by (PE / electrician / inspector)
License number
Signature
This sheet is an estimate for ordering and layout discussion. It is not a sealed design. Confirm the quantities with a licensed local professional and the authority having jurisdiction before you buy or build.
Engineering notes
This calculator is designed to assist in determining the specifications for a residential concrete slab measuring 16 feet by 12 feet and 5 inches thick, reinforced with #4 bars at 18 inches on center. Please note that soil design considerations are excluded from this calculation.
For compliance with the International Residential Code (IRC) R506, ensure that all local building codes and regulations are followed during construction.
Code reference
IRC R506
Field questions
- What is the purpose of using #4 bars in the slab?
- The #4 bars provide reinforcement to the concrete slab, helping to control cracking and improve structural integrity.
- Why is soil design excluded from this calculation?
- Soil design is a complex aspect that depends on various factors such as soil type, load-bearing capacity, and local conditions, which are not covered in this calculator.
- What thickness is recommended for a residential slab?
- A thickness of 5 inches is commonly recommended for residential slabs, but it may vary based on specific project requirements and local codes.
- How do I ensure compliance with IRC R506?
- To ensure compliance, follow the guidelines set forth in IRC R506 regarding slab thickness, reinforcement, and other construction practices. Consulting a licensed professional is also advisable.
Explore Related Engineering Calculations
- 14 by 12 ft slab at 8 inches
- 14 by 14 ft slab at 4 inches
- 8 by 8 ft slab at 8 inches
- 8 by 10 ft slab at 4 inches
- 14 by 14 ft slab at 5 inches
- 14 by 14 ft slab at 6 inches
- 50 Amp EV Charger Wire Size at 50, 75, and 100 Feet
- Deck Stair Stringer Calculator, 36 to 96 Inch Rise
- 6/12 Roof Pitch, Rafter Length, and Shingle Bundles
- 20 ft dry, US 48×40 pallets: Pallet Count, CBM, and Payload